Accelerated corrosion of steel in dry-cast reinforced concrete pipes after initiation
- Date Issued:
- 2014
- Summary:
- Instrumented dry-cast reinforced concrete pipe (DC-RCP) specimens in which corrosion of the reinforcing steel had initiated were selected to accelerate the corrosion. Type C and type F DC-RCP were used. An anodic current density of various magnitudes (0.5 μA/cm2, 1 μA/cm2 and 2.5 μA/cm2) was applied during the corrosion propagation stage. The specimens were placed in high humidity and selected specimens were later covered with wet sand. Selected specimens were terminated for visual examination and gravimetric analysis. Typically, the reinforcement potentials during the accelerated corrosion period were more negative for F specimens compared to C specimens. The C specimens experienced ~2× more corrosion than the F specimens. The accumulated corrosion products did not cause cracks. A method was developed that allows for modest corrosion acceleration during the corrosion propagation stage of DC-RCP.
Title: | Accelerated corrosion of steel in dry-cast reinforced concrete pipes after initiation. |
389 views
278 downloads |
---|---|---|
Name(s): |
Weber, Brian W., author Presuel-Moreno, Francisco, Thesis advisor Florida Atlantic University, Degree grantor College of Engineering and Computer Science Department of Ocean and Mechanical Engineering |
|
Type of Resource: | text | |
Genre: | Electronic Thesis Or Dissertation | |
Date Created: | 2014 | |
Date Issued: | 2014 | |
Publisher: | Florida Atlantic University | |
Place of Publication: | Boca Raton, Fla. | |
Physical Form: | application/pdf | |
Extent: | 109 p. | |
Language(s): | English | |
Summary: | Instrumented dry-cast reinforced concrete pipe (DC-RCP) specimens in which corrosion of the reinforcing steel had initiated were selected to accelerate the corrosion. Type C and type F DC-RCP were used. An anodic current density of various magnitudes (0.5 μA/cm2, 1 μA/cm2 and 2.5 μA/cm2) was applied during the corrosion propagation stage. The specimens were placed in high humidity and selected specimens were later covered with wet sand. Selected specimens were terminated for visual examination and gravimetric analysis. Typically, the reinforcement potentials during the accelerated corrosion period were more negative for F specimens compared to C specimens. The C specimens experienced ~2× more corrosion than the F specimens. The accumulated corrosion products did not cause cracks. A method was developed that allows for modest corrosion acceleration during the corrosion propagation stage of DC-RCP. | |
Identifier: | FA00004233 (IID) | |
Degree granted: | Thesis (M.S.)--Florida Atlantic University, 2014. | |
Collection: | FAU Electronic Theses and Dissertations Collection | |
Note(s): | Includes bibliography. | |
Subject(s): |
Concrete -- Deterioration Corrosion and anti corrosives Pipelines -- Design and construction Tubular steel structures -- Deterioration |
|
Held by: | Florida Atlantic University Libraries | |
Sublocation: | Digital Library | |
Links: | http://purl.flvc.org/fau/fd/FA00004233 | |
Persistent Link to This Record: | http://purl.flvc.org/fau/fd/FA00004233 | |
Use and Reproduction: | Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder. | |
Use and Reproduction: | http://rightsstatements.org/vocab/InC/1.0/ | |
Host Institution: | FAU | |
Is Part of Series: | Florida Atlantic University Digital Library Collections. |