You are here

4D-CT Lung Registration and its Application for Lung Radiation Therapy

Download pdf | Full Screen View

Date Issued:
2012
Abstract/Description:
Radiation therapy has been successful in treating lung cancer patients, but its efficacy is limited by the inability to account for the respiratory motion during treatment planning and radiation dose delivery. Physics-based lung deformation models facilitate the motion computation of both tumor and local lung tissue during radiation therapy. In this dissertation, a novel method is discussed to accurately register 3D lungs across the respiratory phases from 4D-CT datasets, which facilitates the estimation of the volumetric lung deformation models. This method uses multi-level and multi-resolution optical flow registration coupled with thin plate splines (TPS), to address registration issue of inconsistent intensity across respiratory phases. It achieves higher accuracy as compared to multi-resolution optical flow registration and other commonly used registration methods. Results of validation show that the lung registration is computed with 3 mm Target Registration Error (TRE) and approximately 3 mm Inverse Consistency Error (ICE). This registration method is further implemented in GPU based real time dose delivery simulation to assist radiation therapy planning.
Title: 4D-CT Lung Registration and its Application for Lung Radiation Therapy.
35 views
18 downloads
Name(s): Min, Yugang, Author
Pattanaik, Sumanta, Committee Chair
Hughes, Charles, Committee Member
Foroosh, Hassan, Committee Member
Santhanam, Anand, Committee Member
University of Central Florida, Degree Grantor
Type of Resource: text
Date Issued: 2012
Publisher: University of Central Florida
Language(s): English
Abstract/Description: Radiation therapy has been successful in treating lung cancer patients, but its efficacy is limited by the inability to account for the respiratory motion during treatment planning and radiation dose delivery. Physics-based lung deformation models facilitate the motion computation of both tumor and local lung tissue during radiation therapy. In this dissertation, a novel method is discussed to accurately register 3D lungs across the respiratory phases from 4D-CT datasets, which facilitates the estimation of the volumetric lung deformation models. This method uses multi-level and multi-resolution optical flow registration coupled with thin plate splines (TPS), to address registration issue of inconsistent intensity across respiratory phases. It achieves higher accuracy as compared to multi-resolution optical flow registration and other commonly used registration methods. Results of validation show that the lung registration is computed with 3 mm Target Registration Error (TRE) and approximately 3 mm Inverse Consistency Error (ICE). This registration method is further implemented in GPU based real time dose delivery simulation to assist radiation therapy planning.
Identifier: CFE0004300 (IID), ucf:49464 (fedora)
Note(s): 2012-05-01
Ph.D.
Engineering and Computer Science, Computer Science
Doctoral
This record was generated from author submitted information.
Subject(s): Optical flow registration -- Radiation therapy
Persistent Link to This Record: http://purl.flvc.org/ucf/fd/CFE0004300
Restrictions on Access: public 2012-05-15
Host Institution: UCF

In Collections