Summary:
The purpose of this study is to investigate the changes of the pericardial dose at different respiratory phases and statuses in accelerated partial breast irradiation (APBI) using Cyberknife M6™ multileaf collimators (CK-MLC). Anonymous 6 female patient files with respiration gated four-dimensional computed tomography (4DCT) sets, and 6 left breast cancer cases with CT images in free-breathing (FB) and deep inhalation breath-hold (BH) were selected. One CT image set from each patient was planned for APBI in Accuray Multiplan™ 5.2, and respectively compared its pericardial dose with those from CT sets of other respiratory phases. All the comparable CT images were fused in the planning system according to the left chest wall, among which the lung gap anterior to the pericardium varies by the lung expansion. For the purpose of this study, the tumor volume was outlined in the media-lower quadrant of the left breast where this lung gap is relatively small. All the plans in this study met the requirements set by the National Surgical Adjuvant Breast and Bowel Project/Radiation Therapy Oncology Group (NSABP/RTOG), specifically protocol B-39/RTOG 0413. From the comparisons in this investigation, the mean relative pericardial dose of the BH CT group showed significant or 45% (p < 0.01) lower value than that of FB CT group. However, in FB 4DCT group, 3 of 6 cases indicated a meaningful reduction (p < 0.05) in 100% inhalation phase when compared with the mean dose over other phases. The inconsistent pericardial doses were displayed in FB 4DCT group due to minimal changes in the anterior lung gap of the pericardium, when the diaphragmatic breathing was dominant in those patients.
Title: Variations of Pericardial Dose at Different Respiratory Status in Accelerated Partial Breast Irradiation (APBI) Using Cyberknife M6™ Multileaf Collimators (CKMLC).
92 views
22 downloads
Name(s): Long, Samanthia C., author
Shang, Charles, Thesis advisor
Leventouri, Theodora, Thesis advisor
Florida Atlantic University, Degree grantor
Charles E. Schmidt College of Science
Department of Physics
Type of Resource: text
Genre: Electronic Thesis Or Dissertation
Date Created: 2015
Date Issued: 2015
Publisher: Florida Atlantic University
Place of Publication: Boca Raton, Fla.
Physical Form: application/pdf
Extent: 49 p.
Language(s): English
Summary: The purpose of this study is to investigate the changes of the pericardial dose at different respiratory phases and statuses in accelerated partial breast irradiation (APBI) using Cyberknife M6™ multileaf collimators (CK-MLC). Anonymous 6 female patient files with respiration gated four-dimensional computed tomography (4DCT) sets, and 6 left breast cancer cases with CT images in free-breathing (FB) and deep inhalation breath-hold (BH) were selected. One CT image set from each patient was planned for APBI in Accuray Multiplan™ 5.2, and respectively compared its pericardial dose with those from CT sets of other respiratory phases. All the comparable CT images were fused in the planning system according to the left chest wall, among which the lung gap anterior to the pericardium varies by the lung expansion. For the purpose of this study, the tumor volume was outlined in the media-lower quadrant of the left breast where this lung gap is relatively small. All the plans in this study met the requirements set by the National Surgical Adjuvant Breast and Bowel Project/Radiation Therapy Oncology Group (NSABP/RTOG), specifically protocol B-39/RTOG 0413. From the comparisons in this investigation, the mean relative pericardial dose of the BH CT group showed significant or 45% (p < 0.01) lower value than that of FB CT group. However, in FB 4DCT group, 3 of 6 cases indicated a meaningful reduction (p < 0.05) in 100% inhalation phase when compared with the mean dose over other phases. The inconsistent pericardial doses were displayed in FB 4DCT group due to minimal changes in the anterior lung gap of the pericardium, when the diaphragmatic breathing was dominant in those patients.
Identifier: FA00004518 (IID)
Degree granted: Thesis (M.S.)--Florida Atlantic University, 2015.
Collection: FAU Electronic Theses and Dissertations Collection
Note(s): Includes bibliography.
Subject(s): Breast--Cancer--Radiotherapy.
Breast--Cancer--Treatment.
Radiation--Measurement--Methodology.
Medical physics.
Held by: Florida Atlantic University Libraries
Sublocation: Digital Library
Links: http://purl.flvc.org/fau/fd/FA00004518
Persistent Link to This Record: http://purl.flvc.org/fau/fd/FA00004518
Use and Reproduction: Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
Use and Reproduction: http://rightsstatements.org/vocab/InC/1.0/
Host Institution: FAU
Is Part of Series: Florida Atlantic University Digital Library Collections.