Summary:
Experiments and analyses were performed to better define the limits of concern regarding hydrogen embrittlement in association with application of cathodic protection to prestressed concrete. To accomplish this, prestressed concrete specimens were locally corroded to different levels by anodic polarization and then polarized to -1.30 V SCE. A procedure of examination was developed using strain gauges to determine the level of prestrain. Relatively few brittle failures of wires resulted due, at least in part, to a relatively low prestrain of the pretensioned tendons. A model was developed which, coupled with data from parallel research, permitted definition of the minimum cross section for brittle failure as a function of the magnitude of prestrain and corrosion morphology of the wire. These results were tabulated in a format that can be used during field inspection to identify structural elements for which fracture could occur upon application of cathodic protection.
Title: Embrittlement susceptibility of corroded pre-stressing steel in concrete during cathodic polarization.
38 views
6 downloads
Name(s): Poeydomenge, Arnaud.
Florida Atlantic University, Degree grantor
Hartt, William H., Thesis advisor
College of Engineering and Computer Science
Department of Ocean and Mechanical Engineering
Type of Resource: text
Genre: Electronic Thesis Or Dissertation
Issuance: monographic
Date Issued: 1997
Publisher: Florida Atlantic University
Place of Publication: Boca Raton, Fla.
Physical Form: application/pdf
Extent: 92 p.
Language(s): English
Summary: Experiments and analyses were performed to better define the limits of concern regarding hydrogen embrittlement in association with application of cathodic protection to prestressed concrete. To accomplish this, prestressed concrete specimens were locally corroded to different levels by anodic polarization and then polarized to -1.30 V SCE. A procedure of examination was developed using strain gauges to determine the level of prestrain. Relatively few brittle failures of wires resulted due, at least in part, to a relatively low prestrain of the pretensioned tendons. A model was developed which, coupled with data from parallel research, permitted definition of the minimum cross section for brittle failure as a function of the magnitude of prestrain and corrosion morphology of the wire. These results were tabulated in a format that can be used during field inspection to identify structural elements for which fracture could occur upon application of cathodic protection.
Identifier: 9780591437225 (isbn), 15417 (digitool), FADT15417 (IID), fau:12184 (fedora)
Collection: FAU Electronic Theses and Dissertations Collection
Note(s): College of Engineering and Computer Science
Thesis (M.S.E.)--Florida Atlantic University, 1997.
Subject(s): Prestressed concrete--Corrosion
Cathodic protection
Prestressed concrete--Embrittlement
Prestressed steel construction
Held by: Florida Atlantic University Libraries
Persistent Link to This Record: http://purl.flvc.org/fcla/dt/15417
Sublocation: Digital Library
Use and Reproduction: Copyright © is held by the author, with permission granted to Florida Atlantic University to digitize, archive and distribute this item for non-profit research and educational purposes. Any reuse of this item in excess of fair use or other copyright exemptions requires permission of the copyright holder.
Use and Reproduction: http://rightsstatements.org/vocab/InC/1.0/
Host Institution: FAU
Is Part of Series: Florida Atlantic University Digital Library Collections.