This study assesses the viability of using a towfish mounted ADV for quantifying water velocity fluctuations in the Florida Current relevant to ocean current turbine performance. For this study a motion compensated ADV is operated in a test flume. Water velocity fluctuations are generated by a 1.3 cm pipe suspended in front of the ADV at relative current speeds of 0.9 m/s and 0.15 m/s, giving Reynolds numbers on the order of 1000. ADV pitching motion of +/- 2.5 [degree] at 0.3 Hz and a heave motion of 0.3 m amplitude at 0.2 Hz are utilized to evaluate the motion compensation approach. The results show correction for motion provides up to an order of magnitude reduction in turbulent kinetic energy at frequencies of motion while the IMU is found to generate 2% error at 1/30 Hz and 9% error at 1/60 Hz in turbulence intensity.
Title: Evaluation of motion compensated ADV measurements for quantifying velocity fluctuations.
84 views
20 downloads
Name(s): Lovenbury, James William.
College of Engineering and Computer Science
Department of Ocean and Mechanical Engineering
Type of Resource: text
Genre: Electronic Thesis Or Dissertation
Date Issued: 2013
Publisher: Florida Atlantic University
Physical Form: electronic
Extent: viii, 68 p. : ill. (some col.)
Language(s): English
Summary: This study assesses the viability of using a towfish mounted ADV for quantifying water velocity fluctuations in the Florida Current relevant to ocean current turbine performance. For this study a motion compensated ADV is operated in a test flume. Water velocity fluctuations are generated by a 1.3 cm pipe suspended in front of the ADV at relative current speeds of 0.9 m/s and 0.15 m/s, giving Reynolds numbers on the order of 1000. ADV pitching motion of +/- 2.5 [degree] at 0.3 Hz and a heave motion of 0.3 m amplitude at 0.2 Hz are utilized to evaluate the motion compensation approach. The results show correction for motion provides up to an order of magnitude reduction in turbulent kinetic energy at frequencies of motion while the IMU is found to generate 2% error at 1/30 Hz and 9% error at 1/60 Hz in turbulence intensity.
Identifier: 860991089 (oclc), 3362482 (digitool), FADT3362482 (IID), fau:4195 (fedora)
Note(s): by James William Lovenbury.
Thesis (M.S.C.S.)--Florida Atlantic University, 2013.
Includes bibliography.
Mode of access: World Wide Web.
System requirements: Adobe Reader.
Subject(s): Motion control systems
Fluid dynamic measurements
Fluid mechanics -- Mathematical models
Analysis of covariance
Persistent Link to This Record: http://purl.flvc.org/fcla/dt/3362482
Use and Reproduction: http://rightsstatements.org/vocab/InC/1.0/
Host Institution: FAU